Ion Chambers

For use with Accu-Gold+ and Accu-Dose+. Ion Chamber Dose Sensors are General Purpose – In-Beam Chamber, Dedicated Mammography Chamber, Service and Image Intensifier Chamber, Chamber for Computed Tomography dose Index and DWP or DLP, Leakage and Low Level Measurements Chamber, Radiation Protection Chamber, High Dose Rate and Modern Wide Beam Multi-Slice CT Chamber.

 

10X6-0.18

10x6-0-18-High-Dose-Rate-Ion-Chamber

The 10X6-0.18 is a High Dose Rate Chamber. For in-beam measurements of high-intensity gamma radiation. Gamma irradiators and beam type irradiators. The fully guarded chamber is mounted at the end of a 3 m low noise triax cable.

Specification Sheet

10x6-0-6-High-Dose-Rate-Ion-ChamberThe 10X6-0.6 is a High Dose Rate Chamber.

This high dose rate chamber provides an excellent response at therapy and other high energy, high dose rate applications. The fully guarded chamber is mounted at the end of a 12 m low noise triax cable. Can be used with or without build up cap depending upon the application.

Specification Sheet

10x6-6-General-Purpose-Ion-ChamberThe 10X6-6 is a General Purpose In Beam Chamber.

A well documented wide dynamic range chamber with many dose and rate applications. Also recommended for measuring exposure time in Auto Dose mode.

Specification Sheet

10x6-6M-Mammography-Ion-ChamberThe 10X6-6M is a Dedicated Mammography Chamber.

A world standard for mammography, ready for any mammographic tube track-filter combination. Extraordinary flat energy response over 10 – 40 keV has been documented in technical papers and makes corrections unnecessary. Also recommended for measuring exposure time in Auto Dose mode.

Specification Sheet

10x6-10-General-Purpose-Ion-ChamberThe 10X6-10 is a General Purpose In Beam Chamber.

This 10cc multi-purpose ion chamber is suitable for measuring R&F as well as fluoro. Its small size (5cm diameter x 1cm thick), excellent energy response and x-ray transparency makes it ideal for those difficult measurements where space is at a minimum.

Specification Sheet

Radcal 10x6-60-Image-Intensifier-Ion-ChamberThe 10X6-60 is a Service and Image Intensifier Chamber.

The dynamic range and thin profile is ideal for Input Dose at the Image Intensifier, High dose rates encountered in Fluoroscopy and Cine, spot film devices & other special procedures.

Specification Sheet

10x6-180-Leakage-Ion-ChamberThe 10X6-180 is a Leakage and Low Level Measurements Chamber.

Designed for leakage measurements. Cross-section of 100 cm2 and volume of 180 cm3. Also for very low dose to image receptor.

Specification Sheet

10x6-1800-Radiation-Protection-Ion-ChamberThe 10X6-1800 is a Radiation Protection Chamber.

For low-level radiation measurements such as shielding leakage, irradiator and environmental. Unlike typical survey meters, the 1800 cm3 volume chamber offers improved accuracy over a wider dynamic range.

Specification Sheet

10x6-0-6ct-High-Dose-Rate-Ion-ChamberThe 10X6-0.6CT is a Modern Wide Beam Multi-Slice CT Chamber.

0.6cc thimble chamber as described in the AAPM Report No. 111 “Comprehensive Methodology for the Evaluation of Radiation Dose in X-ray Computed Tomography.” Ideal for dose measurements in modern wide beam multi-slice CT. Calibrated using X-rays @ 150 kVp, Phantom adapter included.

Specification Sheet

10x6-3ct-CT-CTDI-Ion-ChamberThe 10X6-3CT is a Computed Tomography Dose Index (CTDI)and DWP or DLP Chamber.

Although designed specifically for CT X-ray beam measurements, either free-in-air or mounted in a head or body phantom, it can be used for DWP and DLP applications such as Dental x-ray measurements, due to the chambers excellent energy and partial volume response as well as uniformity along its entire 10 cm active length.

Specification Sheet

DAPcheck Plus DAP Check Light Field Congruence

Leakage Measurement Chamber

A single sensor leakage measurement solution for very low-level radiation measurements such as shielding, leakage, irradiators and environmental that is part of the Accu-Gold family of systems. Equivalent to the Fluke® 96010A Ion Chamber used in the Fluke® Radiation Leakage Detection System, this chamber meets 21 CFR 1020.30(k) for leakage measurement requirements.